Hello Douglas and community members,
I have a similar situation with CRM Production Upgrade. I used the tcode RSTCO_ADMIN , before starting the installation status was red and then changed to yellow. When displaying the log for today I see many error entries.
All the other users are still locked as the part of Upgrade activity, am i right to perform these actions at this point of time only??
Below in the LONGPOST. Please help. Awaiting the reply.
A2PEBRAIN 071 Could not enter characteristic value "0LANGU" with SID "2" in table
"/BI0/SIOBJNM""0IOBJNM"
Long text: see above
A2PERSTCO_UT 003 An error occurred while activating BW object &2"0TCAIFAREA" (&1"IOBJ")&3"OM"
Long text: see above
A2PEBRAIN 071 Could not enter characteristic value "0BUCKET" with SID "2" in table
"/BI0/SIOBJNM""0IOBJNM"
Long text: see above
A2PERSTCO_UT 003 An error occurred while activating BW object &2"0CHNGID" (&1"IOBJ")&3"OM"
Long text: see above
A2PEBRAIN 071 Could not enter characteristic value "0HIENM" with SID "2" in table
"/BI0/SIOBJNM""0IOBJNM"
Long text: see above
A2PERSTCO_UT 003 An error occurred while activating BW object &2"0HIER_HIEID" (&1"IOBJ")&3"OM"
A2PEBRAIN 071 Could not enter characteristic value "0HIER_HIEID" with SID "2" in table
"/BI0/SIOBJNM""0IOBJNM"
A2PERSTCO_UT 003 An error occurred while activating BW object &2"0HIER_NODE" (&1"IOBJ")&3"OM"
A2PEBRAIN 071 Could not enter characteristic value "0HIER_NODE" with SID "2" in table
"/BI0/SIOBJNM""0IOBJNM"
A2PERSTCO_UT 003 An error occurred while activating BW object &2"0HIER_VERS" (&1"IOBJ")&3"OM"
A2PEBRAIN 071 Could not enter characteristic value "0HIER_VERS" with SID "2" in table
"/BI0/SIOBJNM""0IOBJNM"
A2PERSTCO_UT 003 An error occurred while activating BW object &2"0INFOPROV" (&1"IOBJ")&3"OM"
A2PEBRAIN 071 Could not enter characteristic value "0INFOPROV" with SID "2" in table
"/BI0/SIOBJNM""0IOBJNM"
A2PERSTCO_UT 003 An error occurred while activating BW object &2"0IOBJNM" (&1"IOBJ")&3"OM"
A2PEBRAIN 071 Could not enter characteristic value "0LANGU" with SID "2" in table
"/BI0/SIOBJNM""0IOBJNM"
A2PERSTCO_UT 003 An error occurred while activating BW object &2"0RATE_TYPE" (&1"IOBJ")&3"OM"
A2PEBRAIN 071 Could not enter characteristic value "0RATE_TYPE" with SID "2" in table
-2-
H:\SAP-Service\KUNDEN\Europapier\crm_7.0_ehp3_up\abap_specific\misc\longpost_epr\LONGPOST.LOG Freitag, 28. August 2015 15:45
"/BI0/SIOBJNM""0IOBJNM"
A2PERSTCO_UT 003 An error occurred while activating BW object &2"0RECORDMODE" (&1"IOBJ")&3"OM"
A2PEBRAIN 071 Could not enter characteristic value "0RECORDMODE" with SID "2" in table
"/BI0/SIOBJNM""0IOBJNM"
A2PERSTCO_UT 003 An error occurred while activating BW object &2"0RECORDTP" (&1"IOBJ")&3"OM"
A2PEBRAIN 071 Could not enter characteristic value "0RECORDTP" with SID "2" in table
"/BI0/SIOBJNM""0IOBJNM"
A2PERSTCO_UT 003 An error occurred while activating BW object &2"0REQUID" (&1"IOBJ")&3"OM"
A2PEBRAIN 071 Could not enter characteristic value "0REQUID" with SID "2" in table
"/BI0/SIOBJNM""0IOBJNM"
A2PERSTCO_UT 003 An error occurred while activating BW object &2"0TCAACTVT" (&1"IOBJ")&3"OM"
A2PEBRAIN 071 Could not enter characteristic value "0TXTMD" with SID "2" in table
"/BI0/SIOBJNM""0IOBJNM"
A2PERSTCO_UT 003 An error occurred while activating BW object &2"0TXTSH" (&1"IOBJ")&3"OM"
A2PEBRAIN 071 Could not enter characteristic value "0TXTSH" with SID "2" in table
"/BI0/SIOBJNM""0IOBJNM"
A2PERSTCO_UT 003 An error occurred while activating BW object &2"0ALEAFNODCH" (&1"IOBJ")&3"OM"
A2PEBRAIN 071 Could not enter characteristic value "0ALEAFNODCH" with SID "2" in table
"/BI0/SIOBJNM""0IOBJNM"
A2PERSTCO_UT 003 An error occurred while activating BW object &2"0ALEAFNODSP" (&1"IOBJ")&3"OM"
A2PEBRAIN 071 Could not enter characteristic value "0ALEAFNODSP" with SID "2" in table
"/BI0/SIOBJNM""0IOBJNM"
A2PERSTCO_UT 003 An error occurred while activating BW object &2"0NODEPOSIT" (&1"IOBJ")&3"OM"
A2PEBRAIN 071 Could not enter characteristic value "0NODEPOSIT" with SID "2" in table
"/BI0/SIOBJNM""0IOBJNM"
A2PERSTCO_UT 003 An error occurred while activating BW object &2"0NORESTNODE" (&1"IOBJ")&3"OM"
A2PEBRAIN 071 Could not enter characteristic value "0NORESTNODE" with SID "2" in table
"/BI0/SIOBJNM""0IOBJNM"
A2PERSTCO_UT 003 An error occurred while activating BW object &2"0SIGNCH" (&1"IOBJ")&3"OM"