Re: Can we directly upgrade SAP ECC6.0 EHP-00 to EHP-06
You can use a standard guides and test on a copy of your system.
View ArticleRe: Can we directly upgrade SAP ECC6.0 EHP-00 to EHP-06
You can check the guides at http://service.sap.com/instguides - just check SUM guide, EhP6 guide and NetWeaver guide. In these guides, you find a list auf notes to check.
View ArticleRe: Can we directly upgrade SAP ECC6.0 EHP-00 to EHP-06
Hello Daniel, Thanks for the replay. I got more information from the below URL https://service.sap.com/erp-ehp-inst I wanted to know, the real issues or clear path if some one has followed related to...
View ArticleRe: Can we directly upgrade SAP ECC6.0 EHP-00 to EHP-06
Hi, Issues are always system specific and standard issues are delivered through sap notes.So to minimise issues in production system, you copy your system and perform the upgrade on a sandbox system....
View Articlebods data migration
Dear supportI need some documents for BODS(business object data source) data migration form 4.7 to ECC and latest releases KIndly send me docu so we can procedd further Regards
View ArticleRe: Manually uninstall shadow instance & reset EHPI after restored from backup?
Hi Sunny , Can you please send the SAP Note 158358 to me at neel_pushkar@hotmail.com , We are at ACT_UPG phase and need to reset the upgrade. It will be great if you can send me the note. Thanks,Neel
View ArticleMove datafile in oracle from one datafile to second datafile
Dearwe have requirement that we need to move datafile from one tablespace to another tablespacewe are on windows 2003 oracle is 10gcould i do wiith simple copy paste command are there any issue in that...
View ArticleRe: Move datafile in oracle from one datafile to second datafile
H Kindly refer the SAP Note 1500199 - Insufficient tablespace to write data.& Oracle link ORACLE-BASE - Renaming or Moving Oracle Files BRSS
View ArticleRe: Move datafile in oracle from one datafile to second datafile
Hi Rajendra, What are you trying to achieve with this ?I believe you should read the association between logical and physical objects of database. A tables space is represented by data files at disk...
View ArticleRe: Move datafile in oracle from one datafile to second datafile
Dear In brtools there is option move datafiles i would like to work on that Regards
View ArticleRe: Move datafile in oracle from one datafile to second datafile
Hi, Moving means changing location not association with tablespaces. Read this Managing Data Files (SAP Library - SAP Database Guide: Oracle (BC-DB-ORA-DBA))Move/Rename SAP Data files from one device...
View ArticleRe: EHP6 upgrade with sum tool
Hi,can we export database of PRD and import in some other system and make that system as PRDYes you can export the database of PRD and import the same to other system,but as per my understandings...
View ArticleRe: EHP6 upgrade with sum tool
Dearyour suggestion are correct as per requirement as of my understanding but how to fill that database gap .can we do system copy instead of export import once the upgrade is done on main servermeans...
View ArticleRe: connection to sap Cancelled mode
Deari rise the issue with SAP and restart the router and its all services Thanks for your reply
View ArticleRe: EHP6 upgrade with sum tool
There is an option to run the shadow instance on a different host called "Use remote shadow instance" in the SUM. You may make use of that. RegardsRB
View ArticleRe: EHP6 upgrade with sum tool
Hi Rajendra Kindly follow the steps & could you share your OS / DB size details 1. System copy from live Production to test system copy, in test system you are going to start the upgrade. 2. Do...
View ArticleRe: EHP6 upgrade with sum tool
Hi, The approach of copy production and restoring database is incorrect on upgraded system.You may land up in trouble after doing this.Have a look at this document which gives you an overview of...
View ArticleRe: EHP6 upgrade with sum tool
Hi sriramwe have already create test system and test is at last level now we need to do that same on PRD systemfor upgrade with SUM it took almost 1 week and we have 10gb ram in test system and we have...
View ArticleRe: EHP6 upgrade with sum tool
There is no need to create a standby system on a new machine. Instead of doing that have you thought of using the remote shadow instance like I have suggested. Moreover with 32 GB memory it is possible...
View ArticleRe: EHP6 upgrade with sum tool
DearThanks for all for your valuable suggestion i will try using of remote shadow like you have suggested tell me the steps Regards